Ultrasonic TransducersOperating Instructions 08/2013XPS10/15F
Page 6 XPS 10/15 F Series Transducer A5E32725813 Mounting Mounting Recommendations Special handling precautions must be taken to protect the f
A5E32725813 XPS 10/15 F Series Transducer Page 7 Mounting Liquid Applications Notes: In, the examples that follow, an XPS 10 F Series transduce
Page 8 XPS 10/15 F Series Transducer A5E32725813 Mounting Blind Flange (XPS 10 F shown) Flange, gasket, hazardous seal and hardware supplied by
A5E32725813 XPS 10/15 F Series Transducer Page 9 interconnection Interconnection Note: Installation should only be performed by qualified personn
Page 10 XPS 10/15 F Series Transducer A5E32725813 Interconnection 2-Wire Extension (XPS 10 F shown) Coaxial Cable (XPS 10 F shown) metal con
A5E32725813 XPS 10/15 F Series Transducer Page 11 Applications Applications Notes: The transducer is to be used only in the manner outlined in
Page 12 XPS 10/15 F Series Transducer A5E32725813 Applications * the use of a TS-3 temperature sensor provides better temperature tracking in ap
A5E32725813 XPS 10/15 F Series Transducer Page 13 Applications Standpipes In many applications, access must be made via a standpipe. In such case
Page 14 XPS 10/15 F Series Transducer A5E32725813 Applications Volume 1. Beam should not detect bin bottom. If this occurs, use range extensio
A5E32725813 XPS 10/15 F Series Transducer Page 15 Applications Water / Wastewater Differential Level Pump Control Sewage Lift
© Siemens AG 2013 Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the pr
Page 16 XPS 10/15 F Series Transducer A5E32725813 Applications Solids Applications Typical 1. Transducer angled to avoid seams in bin wall and a
A5E32725813 XPS 10/15 F Series Transducer Page 17 Applications 4. On fluid like solids, aim transducer perpendicular to material surface. 5. O
Page 18 XPS 10/15 F Series Transducer A5E32725813 Applications Special Storage Bin with Agitator 1. Transducer should be kept away from infeed.
A5E32725813 XPS 10/15 F Series Transducer Page 19 Applications Dryer - Wood Chips 1. Transducer should be mounted perpendicular to slope of wood
Page 20 XPS 10/15 F Series Transducer A5E32725813 Installation Diagram Installation Diagram for the XPS 10 F
NotesNotes.fm Page 1 Thursday, October 11, 2001 8:48 AM
NotesNotes.fm Page 2 Thursday, October 11, 2001 8:48 AM
www.siemens.com/processautomationPrinted in Canada*A5E32725813*www.siemens.com/continuous-weighingwww.siemens.com/levelFor more informationwww.siemens
A5E32725813 XPS 10/15 F Series Transducer Page i Table of Contents Table of Contents ...
Page ii XPS 10/15 F Series Transducer A5E32725813
A5E32725813 XPS 10/15 F Series Transducer Page 1 About the… About Siemens’ Transducers This product is intended for use in industrial areas. Oper
Page 2 XPS 10/15 F Series Transducer A5E32725813 Specifications Specifications XPS 10 F Series Transducers Measurement Range: 0.3 – 10m (1 – 3
A5E32725813 XPS 10/15 F Series Transducer Page 3 Specifications XPS 15 F Series Transducers Measurement Range: 0.45 – 15m (1.5 – 50ft) Frequenc
Page 4 XPS 10/15 F Series Transducer A5E32725813 Outline & Dimensions Outline and Dimensions XPS 10 F Series Transducers Standard Flange (opti
A5E32725813 XPS 10/15 F Series Transducer Page 5 Outline & Dimensions XPS 15 F Series Transducers Standard Flange (optional) Split Flange