SECTION TWO - FRONT PANEL OPERATION
F5 (Send) Main-Util-RS232-Send
When F5 (Send) is depressed, the following keys appear.
After selecting F1 (Text) or F2 (Conv), select which programs you want to send to the off-line
computer from the menu. These actions will display the following menu.
F1 (Begin) starts transmission of the active send program that is shown in the upper right-hand
corner.
F7 (Menu) allows selection of programs from a menu to send.
Notes on Send
Note 1: If sending parameters, F7(Menu) is not an option.
Note 2: The RS-232 parameters must be set to the same values on both the control and the
computer. Always check these parameter settings.
Note 3: The RS-232 parameters are found in the control parameters (Main-Parms-Ctrl).
Normal parameter settings are:
Primary Port COM1
Baud rate 1200 through 9600
Parity Even
Data bits 7
Stop bits 2
F6 (Recev) Main-Util-RS232-Recev
The F6 (Recev) option is used to receive programs or parameters from an off-line computer into
the control program memory. Upon pressing the F6 (Recev) key, a new set of selection keys will
appear as shown below. Then a new program number must be entered in the message window.
Once a valid program number has been entered, the edit screen will appear and display the
program as it is received. Receiving will continue until the ESC (Done) key is pressed.
101